Access Control
3 guides · 21 min total
Controllers, readers and credentials.
- Panel Installation11 sections · 8 min read
- Reader Wiring: Wiegand & OSDP4 sections · 6 min read
- Credentials & Cloning Risk9 sections · 7 min read

Step-by-step installation and setup guides for CCTV, access control and alarm systems, written by the Connixtech technical team.
3 guides · 21 min total
Controllers, readers and credentials.
3 guides · 19 min total
Positioning, recording and remote access.
3 guides · 19 min total
Panel programming, zones and monitoring.
RF signal survey, device enrolment, battery maintenance.
Motor sizing, mechanical setup, photocells and force limits.
Intercom, PA system and PoE network guides.
At the far end of the loop, inside the last device on that zone. A resistor at the panel end defeats the purpose entirely, because anyone can cut the cable at the detector and the panel will still read sealed.
Read the guide: Alarm Zone Configuration and Wiring →No. All three New Zealand mobile operators completed their 3G shutdowns by 31 March 2026. Any 3G communicator must be replaced with a 4G unit. The panel will often show no fault, so this needs checking physically.
Read the guide: Alarm Communicator Setup (IP and 4G) →Yes. Security system installation work is regulated under the Private Security Personnel and Private Investigators Act 2010 and requires the appropriate licence or certificate of approval.
Read the guide: Alarm Panel Programming Guide →Divide 2 TB by your daily storage figure. Eight 4 MP H.265 cameras at 4 Mbps recording continuously consume roughly 337 GB per day, so a 2 TB drive gives about six days. One camera on the same settings gives around 47 days. Motion-only recording extends both substantially.
Read the guide: NVR/DVR Setup Guide →Most likely CGNAT — the site has no public IP of its own. Compare the router's WAN address against an external IP lookup; a WAN address in the 100.64.0.0/10 range confirms it. Use P2P instead, or ask the ISP for a public IP.
Read the guide: CCTV Remote Viewing Configuration →Around 2.0 to 2.5 m where you need to identify faces, and 3.0 to 4.0 m for general overview. Higher is not better, because it trades face detail for coverage.
Read the guide: CCTV Camera Mounting and Positioning →For new work, yes. Wiegand transmits the credential in clear and is unsupervised, so a cut cable looks like an idle reader. OSDP with Secure Channel encrypts the link and reports when a reader stops responding.
Read the guide: Access Control Reader Wiring: Wiegand and OSDP →Yes, trivially. EM4100, EM4200 and HID Prox transmit a fixed number with no encryption or authentication. Writable blank tags that emulate them cost a few dollars and copying takes seconds.
Read the guide: Access Control Credentials: Programming, Formats and Cloning Risk →